Ease of Use Features
- Wave Inspector® Controls Provide Easy Navigation and Automated
Search of Waveform Data
- FilterVu™ Variable Low-pass Filter
Allows for Removal of Unwanted Signal Noise while still Capturing
High-frequency Events
- 29 Automated Measurements, and FFT
Analysis for Simplified Waveform Analysis
- TekVPI® Probe Interface Supports Active, Differential, and Current Probes
for Automatic Scaling and Units
- 7 in. (180 mm) Widescreen
TFT-LCD Color Display
- Small Footprint and Lightweight – Only
5.3 in. (134 mm) deep and 7 lb. 14 oz. (3.6 kg)
Connectivity
- USB 2.0 Host Port on the Front Panel for Quick and Easy
Data Storage
- USB 2.0 Device Port on Rear Panel for Easy Connection
to a PC or Direct Printing to a PictBridge®-compatible
Printer
- Optional 10/100 Ethernet Port for Network Connection
and Video Out Port to Export the Oscilloscope Display to a Monitor
or Projector
Optional Serial Triggering and Analysis
- Automated Serial Triggering, Decode, and Search Options
for I2C, SPI, CAN, LIN, and RS-232/422/485/UART
Mixed Signal Design and Analysis (MSO Series)
- Automated Triggering, Decode, and Search on Parallel Buses
- Multichannel Setup and Hold Triggering
Feature-rich
Tools for Debugging Mixed Signal Designs
Offering up to 200 MHz
bandwidth and 1 GS/s sample rate, the MSO/DPO2000 Mixed Signal Oscilloscope
Series delivers advanced debug features at an entry-level price. With
up to 20 channels for analyzing analog and digital signals, you can
quickly find and diagnose problems in complex designs. To capture
long windows of signal activity while maintaining fine timing resolution,
the MSO/DPO2000 offers a deep record length of 1 Mpoints standard
on all channels.
With Wave Inspector® controls for
rapid waveform navigation and automated serial and parallel bus analysis,
the MSO/DPO2000 Oscilloscope Series from Tektronix provides the feature-rich
tools you need to simplify and speed debug of your complex design.
Comprehensive Features Speed Every Stage of Debug
The
MSO/DPO2000 Series offers a robust set of features to speed every
stage of debugging your design – from quickly discovering an anomaly
and capturing it, to searching your waveform record for the event
and analyzing its characteristics and your device’s behavior.
Discover – A waveform capture rate of 5,000 wfm/s maximizes
the probability of capturing elusive glitches and other infrequent
events.
Discover
To debug a design
problem, first you must know it exists. Every design engineer spends
time looking for problems in their design, a time-consuming and frustrating
task without the right debug tools.
The MSO/DPO2000 Series
offers complete visualization of signals, providing fast insight into
the real operation of your device. A waveform capture rate of 5,000
waveforms per second enables you to see glitches and other infrequent
transients quickly, revealing the true nature of device faults. A
digital phosphor display with intensity grading shows the history
of a signal’s activity by intensifying areas of the signal that occur
more frequently, providing a visual display of just how often anomalies
occur.
Capture – Triggering on a specific transmit data
packet going across an RS-232 bus. A complete set of triggers, including
triggers for specific serial packet content, ensures you quickly capture
your event of interest.
Capture
Discovering
a device fault is only the first step. Next, you must capture the
event of interest to identify root cause.
The MSO/DPO2000 Series
provides a complete set of triggers – including runt, logic, pulse
width/glitch, setup/hold violation, serial packet, and parallel data
– to help quickly find your event. With up to a 1 Mpoint record length,
you can capture many events of interest, even thousands of serial
packets, in a single acquisition for further analysis while maintaining
high resolution to zoom in on fine signal details.
From triggering
on specific packet content to automatic decode in multiple data formats,
the MSO/DPO2000 Series provides integrated support for a broad range
of serial buses – I2C, SPI, CAN, LIN, and RS-232/422/485/UART.
The ability to decode up to two serial and/or parallel buses simultaneously
means you gain insight into system-level problems quickly.
To further help troubleshoot system-level interactions in complex
embedded systems, the MSO2000 Series offers 16 digital channels in
addition to its analog channels. Since the digital channels are fully
integrated into the oscilloscope, you can trigger across all input
channels, automatically time-correlating all analog, digital, and
serial signals.
Search – I2C decode showing results from a Wave Inspector search for Address
value 50. Wave Inspector controls provide unprecedented efficiency
in viewing and navigating waveform data.
Search
Finding your event of interest in a long waveform record can
be time consuming without the right search tools. With today’s record
lengths pushing to a million data points, locating your event can
mean scrolling through thousands of screens of signal activity.
The MSO/DPO2000 Series offers the industry’s most comprehensive
search and waveform navigation with its innovative Wave Inspector® controls. These controls speed panning and zooming through
your record. With a unique force-feedback system, you can move from
one end of your record to the other in just seconds. User marks allow
you to mark any location that you may want to reference later for
further investigation. Or, automatically search your record for criteria
you define. Wave Inspector will instantly search your entire record,
including analog, digital, and serial bus data. Along the way it will
automatically mark every occurrence of your defined event so you can
quickly move between events.
Analyze – FFT analysis
of a pulsed signal. A comprehensive set of integrated analysis tools
speeds verification of your design’s performance.
Analyze
Verifying that your prototype’s performance
matches simulations and meets the project’s design goals requires
analyzing its behavior. Tasks can range from simple checks of rise
times and pulse widths to sophisticated power loss analysis and investigation
of noise sources.
The MSO/DPO2000 Series offers a comprehensive
set of integrated analysis tools including waveform- and screen-based
cursors, 29 automated measurements, and FFT analysis. Specialized
application support for serial bus analysis is also available.
For extended analysis, National Instrument’s LabVIEW SignalExpress™
Tektronix Edition provides over 200 built-in functions including time
and frequency domain analysis, limit testing, data logging, and customizable
reports.
Wave Inspector controls provide unprecedented
efficiency in viewing, navigating, and analyzing waveform data. Zip
through your 1 Mpoint record by turning the outer pan control (1).
Get from the beginning to end in seconds. See something of interest
and want to see more details? Just turn the inner zoom control (2).
Wave Inspector® Navigation and Search
A 1 Mpoint record length represents thousands of screens of information.
The MSO/DPO2000 Series enables you to find your event in seconds with
Wave Inspector, the industry’s best tool for navigation and search.
Wave Inspector offers the following innovative controls:
Zoom/Pan
A dedicated, two-tier front-panel control provides
intuitive control of both zooming and panning. The inner control adjusts
the zoom factor (or zoom scale); turning it clockwise activates zoom
and goes to progressively higher zoom factors, while turning it counterclockwise
results in lower zoom factors and eventually turning zoom off. No
longer do you need to navigate through multiple menus to adjust your
zoom view. The outer control pans the zoom box across the waveform
to quickly get to the portion of waveform you are interested in. The
outer control also utilizes force-feedback to determine how fast to
pan on the waveform. The farther you turn the outer control, the faster
the zoom box moves. Pan direction is changed by simply turning the
control the other way.
Play/Pause
A dedicated Play/Pause front-panel button scrolls the waveform across the display automatically
while you look for anomalies or an event of interest. Playback speed
and direction are controlled using the intuitive pan control. Once
again, turning the control further makes the waveform scroll faster
and changing direction is as simple as turning the control the other
way.
Search step 1: You define what you would like
to find.
Search step 2: Wave Inspector
automatically searches through the record and marks each event with
a hollow white triangle. You can then use the Previous and Next buttons to jump from one event to the next.
User Marks
Press the Set Mark front-panel
button to place one or more marks on the waveform. Navigating between
marks is as simple as pressing the Previous (←) and Next (→) buttons on the front panel.
Search Marks
The Search button allows you to automatically search through your
long acquisition looking for user-defined events. All occurrences
of the event are highlighted with search marks and are easily navigated
to, using the front-panel Previous (←) and Next (→)
buttons. Search types include edge, pulse width/glitch, runt, logic,
setup and hold, rise/fall time parallel bus, and I2C, SPI,
CAN, LIN, and RS-232/422/485/UART packet content.
Digital phosphor technology enables a 5,000 wfm/s waveform
capture rate and real-time intensity grading on the MSO/DPO2000 Series.
Digital Phosphor Technology
The MSO/DPO2000
Series’ digital phosphor technology provides you with fast insight
into the real operation of your device. Its waveform capture rate
of 5,000 wfm/s gives you a high probability of quickly seeing the
infrequent problems common in digital systems: runt pulses, glitches,
timing issues, and more.
Waveforms are superimposed with one
another and waveform points that occur more frequently are intensified.
This quickly highlights the events that over time occur more often
or, in the case of infrequent anomalies, occur less often.
With the MSO/DPO2000 Series, you can choose infinite persistence
or variable persistence, determining how long the previous waveform
acquisitions stay on-screen. This allows you to determine how often
an anomaly is occurring.
The MSO Series provides
16 integrated digital channels enabling you to view and analyze time-correlated
analog and digital signals.
Mixed Signal Design
and Analysis(MSO Series)
The MSO2000 Series Mixed Signal Oscilloscopes
provide 16 digital channels. These channels are tightly integrated
into the oscilloscope's user interface, simplifying operation and
making it possible to solve mixed-signal issues easily.
With the color-coded digital waveform display, groups are
created by simply placing digital channels together on the screen,
allowing the digital channels to be moved as a group. You can set
threshold values for each pod of eight channels, enabling support
for up to two different logic families.
Color-coded
Digital Waveform Display
The MSO2000 Series has redefined
the way you view digital waveforms. One common problem shared by both
logic analyzers and mixed-signal oscilloscopes is determining if data
is a one or a zero when zoomed in far enough that the digital trace
stays flat all the way across the display. The MSO2000 Series has
color-coded digital traces, displaying ones in green and zeros in
blue.
White edges indicate additional information is
available by acquiring at a higher sample rate.
The multiple transition detection hardware of the MSO2000 Series
will show you a white edge on the display when the system detects
multiple transitions. This acts as a visual reminder that increasing
the sample rate on the next acquisition will reveal higher frequency
information than your previous settings could acquire.
The
MSO2000 Series simplifies channel setup by allowing you to group digital
waveforms and enter waveform labels by using a USB keyboard. By simply
placing digital waveforms next to each other, they form a group. Once
a group is formed, you can position all the channels contained in
that group collectively. This greatly reduces the normal setup time
associated with positioning channels individually.
The P6316 MSO probe offers two eight-channel pods to simplify
connecting to your device.
P6316 MSO Probe
This unique probe design offers two eight-channel pods, simplifying
the process of connecting to the device-under-test. When connecting
to square pins, the P6316 can connect directly to 8×2 square pin headers
spaced on tenth-inch centers. When more attachment flexibility is
required, you can use the included flying lead sets and grabbers to
clip onto surface mount devices or test points. The P6316 offers outstanding
electrical characteristics applying only 8 pF of capacitive loading
with 101 kΩ input impedance.
Output of DAC Signal
– Notice how FilterVu™ clearly shows the noise-free steps of the DAC
in the foreground trace (yellow) which has removed all frequencies
above 5.5 kHz. FilterVu also captures and displays high-frequency
glitches up to the full bandwidth of the oscilloscope in the background
trace (orange).
FilterVu™ Variable Low-pass
Filter
Tired of being limited to a 20 MHz bandwidth filter
in your oscilloscope? Simply turn on FilterVu and adjust the variable
low-pass noise filter. Unlike other variable low-pass filters, FilterVu
filters out the unwanted noise from your signal while still capturing
glitches and other signal details up to the full bandwidth of the
oscilloscope. It does this by showing two waveforms: a waveform that
can be filtered (foreground waveform) and a glitch capture waveform
(background waveform).
The filtered waveform uses a variable
low-pass filter to block out noise, yielding a cleaner waveform to
more precisely locate signal edges and amplitude levels. The result
is improved confidence in you cursor measurements and cleaner documentation
of important signal attributes. When the noise filter is adjusted
to the lowest available noise-cutoff frequency, no more than 1% of
high-frequency content that could cause the oscilloscope to alias
will pass through the filter.
The glitch capture waveform shows
signal details up to the full bandwidth of the oscilloscope. The oscilloscope
captures pulses as narrow as 5 ns, using peak-detect min/max sampling,
protecting you from missing unexpected glitches or other high-frequency
events.
FilterVu is ideal for repetitive, nonrepetitive, and
single-shot events.
Triggering on a specific
data packet going across an I2C bus. The yellow waveform
is clock and the blue waveform is data. A bus waveform provides decoded
packet content including Start, Address, Read/Write, Data, and Stop.
Serial Triggering and Analysis (Optional)
On a serial bus, a single signal often includes address, control,
data, and clock information. This can make isolating events of interest
difficult. The MSO/DPO2000 Series offers a robust set of tools for
debugging serial buses with automatic trigger, decode, and search
for I2C, SPI, CAN, LIN, and RS-232/422/485/UART.
Serial Triggering
Trigger on packet content such as start
of packet, specific addresses, specific data content, unique identifiers,
etc. on popular serial interfaces such as I2C, SPI, CAN,
LIN, and RS-232/422/485/UART.
Bus Display
Provides
a higher-level, combined view of the individual signals (clock, data,
chip enable, etc.) that make up your bus, making it easy to identify
where packets begin and end and identifying subpacket components such
as address, data, identifier, CRC, etc.
Bus Decoding
Tired of having to visually inspect the waveform to count clocks,
determine if each bit is a 1 or a 0, combine bits into bytes, and
determine the hex value? Let the oscilloscope do it for you! Once
you’ve set up a bus, the MSO/DPO2000 Series will decode each packet
on the bus, and display the value in hex, binary, decimal (LIN only),
or ASCII (RS-232/422/485/UART only) in the bus waveform.
Event table showing decoded Identifier, DLC, DATA, and CRC
for every CAN packet in a long acquisition.
Event Table
In addition to seeing decoded packet data on
the bus waveform itself, you can view all captured packets in a tabular
view much like you would see in a software listing. Packets are time
stamped and listed consecutively with columns for each component (Address,
Data, etc.).
Search
Serial triggering is very useful
for isolating the event of interest, but once you’ve captured it and
need to analyze the surrounding data, what do you do? In the past,
users had to manually scroll through the waveform counting and converting
bits and looking for what caused the event. With the MSO/DPO2000 Series,
you can have the oscilloscope automatically search through the acquired
data for user-defined criteria including serial packet content. Each
occurrence is highlighted by a search mark. Rapid navigation between
marks is as simple as pressing the Previous (←) and Next (→) buttons on the front panel.
Designed to Make Your Work
Easier
The MSO/DPO2000 is designed to make your work
easier. The bright, widescreen display shows a long time window. Dedicated
front-panel controls simplify operation. A USB host port on the front
panel allows you to easily transfer screenshots, instrument settings,
and waveform data to a memory stick.
Bright,
Widescreen Display
The MSO/DPO2000 Series features a 7 inch
(180 mm) widescreen, TFT-LCD display for seeing intricate signal details.
Dedicated Front-panel Controls
Per-channel vertical
controls provide simple and intuitive operation. No longer do you
need to share one set of vertical controls across all four channels.
Connectivity
A USB host port on the front panel enables
easy transfer of screenshots, instrument settings, and waveform data
to a USB thumb drive. The rear panel contains a USB device port for
controlling the oscilloscope remotely from a PC or for connecting
a USB keyboard. The USB device port can also be used to print directly
to a PictBridge®-compatible printer. An optional 10/100
Ethernet port enables easy connection to networks and an optional
Video Out port allows the oscilloscope display to be exported to an
external monitor or projector.
The MSO/DPO2000 Series’
compact form factor frees up valuable space on your bench or desktop.
Compact Form Factor
A compact, portable
form factor allows the MSO/DPO2000 Series to be easily moved between
labs and, with a depth of just 5.3 inches (134 mm), it saves you valuable
space on your test bench.
TekVPI probe interface
simplifies connecting your probes to the oscilloscope.
TekVPI® Probe Interface
The TekVPI
probe interface sets the standard for ease of use in probing. TekVPI
probes feature status indicators and controls, as well as a probe
menu button right on the comp box itself. This button brings up a
probe menu on the oscilloscope display with all relevant settings
and controls for the probe. TekVPI probes can be controlled remotely
through USB, GPIB, or Ethernet, enabling more versatile solutions
in ATE environments.
NI LabVIEW SignalExpress™
Tektronix Edition is a fully interactive measurement acquisition and
analysis software developed jointly with National Instruments and
optimized for the MSO/DPO Series.
OpenChoice® Desktop software enables seamless
connection between the oscilloscope and your PC.
Extended Analysis
Acquiring data and measurements from
the MSO/DPO2000 Series is as simple as connecting a USB cable from
the oscilloscope to your PC. Key software applications – NI LabVIEW
SignalExpress™ Tektronix Edition LE, OpenChoice® Desktop,
and Microsoft Excel and Word toolbars – are included standard with
each oscilloscope to enable fast and easy direct communication with
your Windows PC.
NI LabVIEW SignalExpress Tektronix Edition
LE enables you to instantly acquire, generate, analyze, compare, import,
and save measurement data and signals using an intuitive drag-and-drop
user interface that does not require any programming. The optional
Professional Version offers over 200 built-in functions that provide
additional signal processing, advanced analysis, sweeping, limit testing,
and user-defined step capabilities.
For simple tasks, the included
OpenChoice Desktop enables fast and easy communication between the
oscilloscope and your PC through USB, GPIB, or LAN for transferring
settings, waveforms, and screen images.
Characteristics
Vertical System Analog Channels
Characteristic
|
MSO2012
DPO2012
|
MSO2014
DPO2014
|
MSO2024
DPO2024
|
Input Channels
|
2
|
4
|
4
|
Analog Bandwidth (-3 dB)*1
|
100 MHz
|
100 MHz
|
200 MHz
|
Calculated Rise Time
|
3.5 ns
|
3.5 ns
|
2.1 ns
|
Hardware Bandwidth Limits
|
20 MHz
|
Input Coupling
|
AC, DC, GND
|
Input Impedance
|
1 MΩ ±2%, 11.5 pF ±2 pF
|
Input Sensitivity Range
|
2 mV/div to 5 V/div
|
Vertical Resolution
|
8 bits
|
Maximum Input Voltage, 1 MΩ
|
300 VRMS with peaks ≤ ±450 V
|
DC Gain Accuracy (with offset set to 0 V)
|
±3% for 10 mV/div to 5 V/div
±4% for 2 mV/div
to 5 mV/div
|
Channel-to-Channel Isolation
(Any Two Channels at Equal
Vertical Scale)
|
≥100:1 at ≤100 MHz
|
100:1 at ≤200 MHz
|
*1 Bandwidth is 20 MHz at 2 mV/div, all
models.
Offset Range
Range
|
1 MΩ
|
2 mV/div to 200 mV/div
|
±1 V
|
>200 mV/div to 5 V/div
|
±25 V
|
Vertical System Digital Channels
Characteristic
|
All MSO2000 Models
|
Input Channels
|
16 Digital (D15 to D0)
|
Thresholds
|
Threshold per set of 8 channels
|
Threshold Selections
|
TTL, CMOS, ECL, PECL, User Defined
|
User-defined Threshold Range
|
±20 V
|
Maximum Input Voltage
|
±40 V
|
Threshold Accuracy
|
±(100 mV +3% of threshold setting)
|
Maximum Input Dynamic Range
|
80 Vpk-pk (threshold setting dependent)
|
Minimum Voltage Swing
|
500 mVpk-pk
|
Input Impedance
|
101 kΩ
|
Probe Loading
|
8 pF
|
Vertical Resolution
|
1 bit
|
Horizontal System Analog Channels
Characteristic
|
MSO2012/2014
DPO2012/2014
|
MSO2024
DPO2024
|
Maximum Sample Rate (all channels)
|
1 GS/s
|
Maximum Record Length
(all channels)
|
1 Mpoints
|
Maximum Duration of Time Captured at Highest Sample Rate
(all channels)
|
1 ms
|
Time-base Range (s/div)
|
4 ns to 100 s
|
2 ns to 100 s
|
Time-base Delay Time Range
|
-10 divisions to 5000 s
|
Channel-to-Channel Deskew Range
|
±100 ns
|
Time-base Accuracy
|
±25 ppm
|
Horizontal System Digital Channels
Characteristic
|
All MSO2000 Models
|
Maximum Sample Rate (when using any of channels D7-D0)
|
1 GS/s (1 ns resolution)
|
Maximum Sample Rate (when using any of channels D15-D8)
|
500 MS/s (2 ns resolution)
|
Maximum Record Length (all channels)
|
1 Mpoints
|
Minimum Detectable Pulse Width
|
5 ns
|
Channel-to-Channel Skew
|
2 ns typical
|
Trigger System
Characteristic
|
Description
|
Main Trigger Modes
|
Auto, Normal, and Single
|
Trigger Coupling
|
DC, HF reject (attenuates >85 kHz), LF reject (attenuates
<65 kHz), noise reject (reduces sensitivity)
|
Trigger Holdoff Range
|
20 ns to 8 s
|
Trigger Signal Frequency Counter
|
Provides a higher accuracy means of identifying the frequency
of trigger signals. Trigger Signal Frequency counter resolution is
6 digits.
|
Trigger Sensitivity
Characteristic
|
Description
|
Internal DC Coupled
|
0.4 divisions from DC to 50 MHz
0.6 divisions > 50 MHz
to 100 MHz
0.8 divisions > 100 MHz to 200 MHz
|
External
(Auxiliary Input)
|
200 mV from DC to 100 MHz, 1x attenuation
|
Trigger Level Range
Characteristic
|
Description
|
Any Channel
|
±4.92 divisions from center of screen
|
External
(Auxiliary Input)
|
±6.25 V, 1x attenuation
±12.5 V, 10x attenuation
|
Trigger Modes
Mode
|
Description
|
Edge
|
Positive or negative slope on any channel or front-panel auxiliary
input. Coupling includes DC, AC, HF reject, LF reject, and noise reject.
|
Pulse Width
|
Trigger on width of positive or negative pulses that are >,
<, =, or ≠ a specified period of time.
|
Runt
|
Trigger on a pulse that crosses one threshold but fails to
cross a second threshold before crossing the first again.
|
Logic
|
Trigger when any logical pattern of channels goes false or
stays true for specified period of time. Any input can be used as
a clock to look for the pattern on a clock edge. Pattern (AND, OR,
NAND, NOR) specified for all analog and digital input channels defined
as High, Low, or Don’t Care.
|
Setup and Hold
|
Trigger on violations of both setup time and hold time between
clock and data present on any of the input channels.
|
Rise/Fall Time
|
Trigger on pulse edge rates that are faster or slower than
specified. Slope may be positive, negative, or either.
|
Video
|
Trigger on line number, all lines, odd, even, or all fields
on NTSC, PAL, and SECAM video signals.
|
I2C (optional)
|
Trigger on Start, Repeated Start, Stop, Missing ACK, Address
(7 or 10 bit), Data, or Address and Data on I2C buses up
to 3.4 Mb/s.
|
SPI (optional)
|
Trigger on SS, MOSI, MISO, or MOSI and MISO on SPI buses up
to 10.0 Mb/s.
|
CAN (optional)
|
Trigger on Start of Frame, Frame Type (data, remote, error,
overload), Identifier (standard or extended), Data, Identifier and
Data, End of Frame, Missing ACK, or Bit Stuffing Error on CAN signals
up to 1 Mb/s. Data can be further specified to trigger on ≤, <,
=, >, ≥, or ≠ a specific data value. User-adjustable sample point
is set to 50% by default.
|
RS-232/422/485/UART (optional)
|
Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx
End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error.
|
LIN (optional)
|
Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup
Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum Errors.
|
Parallel (available on MSO models only)
|
Trigger on a parallel bus data value.
|
Acquisition Modes
Mode
|
Description
|
Sample
|
Acquire sampled values.
|
Peak Detect
|
Captures glitches as narrow as 3.5 ns at all sweep speeds.
|
Averaging
|
From 2 to 512 waveforms included in average.
|
Roll
|
Scrolls waveforms right to left across the screen at sweep
speeds slower than or equal to 40 ms/div.
|
Waveform Measurements
Measurement
|
Description
|
Cursors
|
Waveform and Screen.
|
Automatic Measurements
|
29, of which up to four can be displayed on-screen at any
one time. Measurements include: Period, Frequency, Delay, Rise Time,
Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse
Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot,
Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min,
Mean, Cycle Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse
Count, Rising Edge Count, Falling Edge Count, Area and Cycle Area.
|
Gating
|
Isolate the specific occurrence within an acquisition to take
measurements on, using either the screen, or waveform cursors.
|
Waveform Math
Characteristic
|
Description
|
Arithmetic
|
Add, subtract, and multiply waveforms.
|
FFT
|
Spectral magnitude. Set FFT Vertical Scale to Linear RMS or
dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris.
|
Software
Product
|
Description
|
NI LabVIEW SignalExpress™ Tektronix Edition
|
A fully interactive measurement software environment optimized
for the MSO/DPO2000 Series, enables you to instantly acquire, generate,
analyze, compare, import, and save measurement data and signals using
an intuitive drag-and-drop user interface that does not require any
programming.
Standard MSO/DPO2000 Series support for acquiring,
controlling, viewing, and exporting your live signal data is permanently
available through the software. The full version (SIGEXPTE) adds additional
signal processing, advanced analysis, mixed signal, sweeping, limit
testing, and user-defined step capabilities and is available for a
30-day trial period standard with each instrument.
|
OpenChoice® Desktop
|
Enables fast and easy communication between a Windows PC and
the MSO/DPO2000 Series. Transfer and save settings, waveforms, measurements,
and screen images. Included Word and Excel toolbars automate the transfer
of acquisition data and screen images from the oscilloscope into Word
and Excel for quick reporting or further analysis.
|
IVI Driver
|
Provides a standard instrument programming interface for common
applications such as LabVIEW, LabWindows/CVI, Microsoft .NET, and
MATLAB.
|
eScope
|
Enables control of the MSO/DPO2000 Series over a network connection
through a standard web browser. Simply enter the IP address or network
name of the oscilloscope and a web page will be served to the browser.
|
Display Characteristics
Characteristic
|
Description
|
Display Type
|
7 in. (180 mm) liquid crystal TFT color display.
|
Display Resolution
|
480 horizontal × 234 vertical pixels (WQVGA).
|
Waveform Styles
|